Difference between revisions of "Config Types"

From OpenMotics
Jump to navigation Jump to search
(Created page with "The config byte is used in in [[Basic Actions}Basic Action]] and specifies the action to be performed. == Versioning == This document describes the Action Type Bytes availabl...")
 
 
(4 intermediate revisions by the same user not shown)
Line 1: Line 1:
The config byte is used in in [[Basic Actions}Basic Action]] and specifies the action to be performed.
+
The config byte is used in [[Simple Action|Simple Actions]] and specifies the action to be performed.
  
 
== Versioning ==
 
== Versioning ==
This document describes the Action Type Bytes available on the [[Master Module]] CLI interface.
+
This document describes the Action Type Bytes available on the [[Gateway Module]] CLI interface.
 
{| class="wikitable"
 
{| class="wikitable"
! Master Module FW version
+
!Gateway Module FW version
 
|-
 
|-
 
|align="center"|3.136
 
|align="center"|3.136
 
|}
 
|}
  
== Action Type Bytes ==
+
== Bytes ==
 
{| class="wikitable" width="60%"
 
{| class="wikitable" width="60%"
!Action Byte
+
! width="5%"|Config Byte
 
!Description
 
!Description
 
|-
 
|-
Line 27: Line 27:
 
|-
 
|-
 
!<div align="center">9</div>
 
!<div align="center">9</div>
|Turn the selected Output on using the timer value specified in the [[Basic Action]]
+
|Turn the selected Output on using the timer value specified in the [[Simple Action]]
 
|-
 
|-
 
!<div align="center">10</div>
 
!<div align="center">10</div>
|Toggle the selected Output using the timer value specified in the [[Basic Action]]
+
|Toggle the selected Output using the timer value specified in the [[Simple Action]]
 
|-
 
|-
 
!<div align="center">19</div>
 
!<div align="center">19</div>

Latest revision as of 22:49, 12 November 2013

The config byte is used in Simple Actions and specifies the action to be performed.

Versioning

This document describes the Action Type Bytes available on the Gateway Module CLI interface.

Gateway Module FW version
3.136

Bytes

Config Byte Description
0
Turn the selected Output off
1
Turn the selected Output on using the standard timer value specified in the output pages
2
Toggle the selected Output using the standard timer value specified in the output pages
3
Clear selected validation bit
9
Turn the selected Output on using the timer value specified in the Simple Action
10
Toggle the selected Output using the timer value specified in the Simple Action
19
Set selected validation bit
35
Toggle selected validation bit