AIO API Event Codes
Jump to navigation
Jump to search
Type | Action | DeviceNr.MSB | DeviceNr.LSB | Data0 | Data1 | Data2 | Data3 | Description |
---|---|---|---|---|---|---|---|---|
0
|
0
|
x.MSB
|
x.LSB
|
y
|
z
|
u.MSB
|
u.LSB
|
Output x off: This Event will be send when an output is switched off with dimmer value y, timer type z and timer value u. See Note 1. |
0
|
1
|
x.MSB
|
x.LSB
|
y
|
z
|
u.MSB
|
u.LSB
|
Output x on: This Event will be send when an output is switched on with dimmer value y, timer type z and timer value u. See Note 1. |
1
|
0
|
x.MSB
|
x.LSB
|
0
|
0
|
0
|
0
|
Input x Released: This Event will be send when an input is released. |
1
|
1
|
x.MSB
|
x.LSB
|
0
|
0
|
0
|
0
|
Input x Pressed: This Event will be send when an input is pressed. |
2
|
0
|
0
|
x
|
0
|
y
|
0
|
0
|
Temperature sensor x changed: This Event will be send when Temperature sensor x has changed, new temperature will be found in y |
2
|
1
|
0
|
x
|
0
|
y
|
0
|
0
|
Humidity sensor x changed: This Event will be send when Humidity sensor x has changed, new humidity will be found in y |
2
|
2
|
0
|
x
|
y.MSB
|
y.LSB
|
0
|
0
|
Brightness sensor x changed: This Event will be send when Brightness sensor x has changed, new humidity will be found in y |
20
|
0
|
0
|
x
|
Mode
|
Setpoint
|
0
|
0
|
Thermostat x has changed: The Thermostat setpoint/mode has been modified by the slave device (For example the Modbus thermostat connected to the Micro CAN has an updated value set by the user) |
20
|
1
|
0
|
x
|
Mode
|
Setpoint
|
0
|
0
|
Thermostat x has changed: The Thermostat setpoint/mode has been modified by the Master device (For example the user has changed the setpoint using the Mobile app) |
251
|
Chip_Nr
|
Led_Blinking_25.MSB
|
Led_Blinking_25.LSB
|
Led_Blinking_50.MSB
|
Led_Blinking_50.LSB
|
Led_Blinking_75.MSB
|
Led_Blinking_75.LSB
|
Front Panel Led state change: When a Led of the Front Panel changes state (from ON to OFF or the reverse), an event message will be send. 2 led driver chips (Chip_nr 0 and 1) are present on the Front panel. The 16 bit Led_blinking_25 will indicate for the 16 leds if the led is blinking at 25% (BIT=1) or not (BIT=0), Led_blinking_50 for 50% and Led_blinking_75 for 75% ON (and thus 25% of the time OFF). |
252
|
Chip_Nr
|
0
|
0
|
Led_status.MSB
|
Led_status.LSB
|
0
|
0
|
Front Panel Led state change: When a Led of the Front Panel changes state (from ON to OFF or the reverse), an event message will be send. 2 led driver chips (Chip_nr 0 and 1) are present on the Front panel. The 16 bit Led_status will indicate for 16 leds if the led is ON (BIT=1) or OFF (BIT=0). |
253
|
0
|
0
|
Bus
|
Power_state
|
0
|
0
|
0
|
Power state change: When Bus=0 -> RS485 Bus, When Bus=1 -> CAN Bus, when Power_state=0 -> Bus OFF, when Power_state=1 -> Bus ON |
254
|
0
|
0
|
0
|
0
|
0
|
0
|
0
|
Eeprom activate has just been fully performed and is finished |
254
|
1
|
0
|
0
|
Onboard_temp
|
0
|
0
|
0
|
Update of the Onboard Main PCB temperature. Temperature is represented as a signed integer. |
Notes:
- Note 1: timer type specifies which kind of timer is active for a given output and his timer value.
- timer type=0: No timer is active
- timer type=1: 100ms timer
- timer type=2: 1s timer
- timer type=3: 1m timer