Difference between revisions of "AIO API Event Codes"

From OpenMotics
Jump to navigation Jump to search
Line 18: Line 18:
 
!<div align="center">u.MSB</div>
 
!<div align="center">u.MSB</div>
 
!<div align="center">u.LSB</div>
 
!<div align="center">u.LSB</div>
|Output x off: This Event will be send when an output is switched off with dimmer value y, timer type z and timer value u.
+
|Output x off: This Event will be send when an output is switched off with dimmer value y, timer type z and timer value u. See Note 1.
 
|-
 
|-
 
!<div align="center">0</div>
 
!<div align="center">0</div>
Line 28: Line 28:
 
!<div align="center">u.MSB</div>
 
!<div align="center">u.MSB</div>
 
!<div align="center">u.LSB</div>
 
!<div align="center">u.LSB</div>
|Output x on: This Event will be send when an output is switched on with dimmer value y, timer type z and timer value u.
+
|Output x on: This Event will be send when an output is switched on with dimmer value y, timer type z and timer value u. See Note 1.
 
|-
 
|-
 
!<div align="center">2</div>
 
!<div align="center">2</div>
Line 60: Line 60:
 
|Brightness sensor x changed: This Event will be send when Brightness sensor x has changed, new humidity will be found in y
 
|Brightness sensor x changed: This Event will be send when Brightness sensor x has changed, new humidity will be found in y
 
|-
 
|-
 +
 +
Notes:
 +
* Note 1: timer type specifies which kind of timer is active for a given output and his timer value.
 +
** timer type=0: No timer is active
 +
** timer type=1: 100ms timer
 +
** timer type=2: 1s timer
 +
** timer type=3: 1m timer

Revision as of 12:50, 16 July 2019

Notes:
  • Note 1: timer type specifies which kind of timer is active for a given output and his timer value.
    • timer type=0: No timer is active
    • timer type=1: 100ms timer
    • timer type=2: 1s timer
    • timer type=3: 1m timer
Type Action DeviceNr.MSB DeviceNr.LSB Data0 Data1 Data2 Data3 Description
0
0
x.MSB
x.LSB
y
z
u.MSB
u.LSB
Output x off: This Event will be send when an output is switched off with dimmer value y, timer type z and timer value u. See Note 1.
0
1
x.MSB
x.LSB
y
z
u.MSB
u.LSB
Output x on: This Event will be send when an output is switched on with dimmer value y, timer type z and timer value u. See Note 1.
2
0
0
x
0
y
0
0
Temperature sensor x changed: This Event will be send when Temperature sensor x has changed, new temperature will be found in y
2
1
0
x
0
y
0
0
Humidity sensor x changed: This Event will be send when Humidity sensor x has changed, new humidity will be found in y
2
2
0
x
y.MSB
y.LSB
0
0
Brightness sensor x changed: This Event will be send when Brightness sensor x has changed, new humidity will be found in y